Overview
- Where Does Izotope Product Portal Downloads Store Files Software
- Where Does Izotope Product Portal Downloads Store Files For Windows 7
- Where Does Izotope Product Portal Downloads Store Files For Mac
- Where Does Izotope Product Portal Downloads Store Files Online
- Where Does Izotope Product Portal Downloads Store Files Free
- Where Does Izotope Product Portal Downloads Store Files Online
IZotope’s Dialogue Match gives your scenes environmental and spatial continuity with just a few clicks from a simple interface. Learn how to best use Dialogue Match in three unique situations.
You can adjust global and module-specific settings in the Options window. You can access the Options window byclicking the gear button in the upper right hand corner of the Ozone interface.
The Options window is divided into three main sections:
- Option Tabs: Options are organized into several different tabs along the top of the Options window.Click on a tab to view and modify the associated options.
- Options Panel: Displays the options available for the selected options tab.
- Options Window Footer: Save, Reset, or Cancel changes to Options.
Options Window Footer
The bottom of the options window includes the following global parameters:
- ?: Opens the Ozone help documentation in your default web browser.
- Reset: Resets all Options in the currently selected options tab to their factory default values.
- Version information: Displays the current Ozone version and build number.
- Cancel: Closes the Options window without saving changes.
- Ok: Closes the Options window and saves changes.
General Tab
The General Options tab allows you to adjust settings related to graphics, authorization, updates, usagetracking and undo history.
Graphics
The following options are included in the Graphics section of the General options tab:
- Show Tooltips: Enables the display of a descriptive text box when hovering your cursor over a control.
- Dim Controls When Bypassed: Enables an overlay that dims the appearance of controls in the modulecontrol panel when Ozone is bypassed.
Authorization & Updates
This section of the General options tab allows you to check for updates and manage your authorization.
Check for Updates
The Check for Updates button has a few different possible states:
- Download Product Portal: To stay up to date with new versions of Relay, download the iZotope ProductPortal application.
- Check for Updates: Manually check for available updates. Clicking this button will open the ProductPortal application and check for updates.
- Download Update: If an update is available, a small blue dot will appear. Clicking the Download Updatebutton in the options window will launch the Product Portal application and display the Updates page.
Authorization
This section allows you to manage your Ozone authorization and displays information about your currentauthorization status.
- Current Authorization Status Text: Displays the current Ozone authorization state.
- Authorize: Opens the iZotope Authorization wizard.
- Remove Authorization: Removes the current authorization.
Other
The Other section of the General options tab includes settings related to usage analysis and undo historydepth.
- Enable Analytics: Enables anonymous usage data to be sent to iZotope to help improve Ozone in thefuture.
- History Depth: Determines the number of parameter change events to store in the Undo History list.
Spectrum Tab
The Spectrum options tab allows you to manage options related to the Spectrum view in all Ozone modules.
Spectrum Type
Selects the type of spectrum display used by spectrum analyzer views in all Ozone modules. The followingoptions are available:
- Linear: A continuous line connecting the calculated points of the spectrum.
- 1/3 Octave: Splits the spectrum into bars with a width of 1/3 of an octave. Although the spectrum issplit into discrete bands, this option can provide excellent resolution at lower frequencies.
- Critical: Splits the spectrum into bands that correspond to how we hear, or more specifically how wedifferentiate between sounds of different frequencies. Each band represents sounds that are considered“similar” in frequency.
- Full Octave: Splits the spectrum into bars with a width of one full octave.
Fill Spectrum
Allows you to display the real-time spectrum as a solid graph as opposed to a line graph. This option can beused to differentiate the real-time spectrum from the peak hold spectrum.
Peak Hold Time (ms)
Sets the length of time the peak hold display will hold before updating. You can choose between specific holdtimes (in milliseconds) or Infinite, where the peak display is held indefinitely.
Show Peak Hold
Toggles whether Ozone displays and holds the peaks of the spectrum.
Window Type
Sets the window type for the spectrum. In most cases the default window type will work well, but you canchoose from a variety of window types. Each window type has different amplitude and frequency resolutioncharacteristics.
Window Size
Set to controls the tradeoff between time and frequency resolution in the spectrum analyzer. Higher valuesoffer greater frequency resolution.
Average Time
Averages the spectrum according to this setting. Higher average times can be useful for viewing the overalltonal balance of a mix, while shorter average times provide a more real-time display. Options include: RealTime, 1 sec, 3 sec, 5 sec, 10 sec, and Infinite.
Frequency Scale
Modifies the distribution of frequencies along the frequency axis of the spectrum analyzer. The defaultfrequency scale is Extended Log.
EQ Tab
The EQ tab includes EQ Spectrum and Performance options. These options will apply to both Equalizer 1 andEqualizer 2 modules.
Spectrum
The following options will affect the spectrum in the Equalizer 1 and 2 modules.
Alt-Solo Filter Q
Sets the bandwidth (Q) of the Alt-Solo feature in the Equalizer module(s).
Show Extra Curves
Toggles the display of Phase Delay, Phase Response, and Group Delay curves in the EQ spectrum.
Performance
- Soft Saturation: Select to enable soft saturation to in the EQ module. When enabled, signals that clipas a result of being boosted by the EQ will saturate with an analog character, rather than harsh digitalclipping.
- Buffer Size: Select to adjusts the memory buffer size, measured in samples, when applying equalizationto the signal.
- Frequency Resolution: Select to set the minimum resolution, in Hz, the Equalizer can be adjusted by. Youcan choose from: 3 Hz, 6 Hz, 12 Hz, 24 Hz, and 48 Hz.
- Filter Size: Displays the calculated steepness of the filter setting used in the EQ module.
Imager Tab
Prevent Antiphase
Where Does Izotope Product Portal Downloads Store Files Software
Select to automatically prevent any settings from being applied that would result in phase cancellation of thestereo signal, when summed to mono.
Vectorscope Detection Method
Select to set which type of amplitude detection method is used by the Vectorscope.
- Peak: When this option is enabled, Ozone’s detection circuit looks at peak levels of the incomingsignal. In general this is useful when you’re trying to even out sudden peaks in your music.
- RMS: When this option is enabled, Ozone looks at the average level of the incoming signal. RMS detectionis useful when you’re trying to increase the overall volume level without changing the character of thesound.
- Envelope: Envelope mode behaves much like RMS mode, but with some key advantages. Unlike RMS, TrueEnvelope mode produces even levels across all frequencies.
I/O Tab
Enable I/O Meters
Select to enable/disable the meters in Ozone’s master I/O section.
Detect True Peaks
Select Detect True Peaks to accurately measure the signal that will result from digital to analog conversion.By default the Input/Output meters will only indicate clipping which occurs within the digital domain.
Enable Legacy Bypass Gain Match Behavior
Select to enable legacy bypass processing on the Gain Match feature in the auditioning section.
Behavior when Legacy Bypass Gain Match is Checked
When Ozone is on there are many modules such as the multiband dynamics and loudness maximizer that can affectthe overall or perceived loudness of the mix. This makes it very hard to compare “Ozone on” to “Ozonebypassed.” The “Automatically Match Effective Gain When Bypassed” feature solves this problem. Ozonedetermines how much perceived gain is being added by all of the active Ozone modules and then automaticallyadds this amount of gain when Ozone is put into bypass mode. You can bypass Ozone, and the gain isautomatically adjusted so that when you A/B Ozone on and off, the apparent volume is the same. This gainprocessing is the only processing that is applied when Ozone is bypassed, and it is of course only appliedwhen Ozone is actually bypassed.
Behavior when Legacy Bypass Gain Match is Unchecked
Enabling Gain Match in the I/O section when this option is disabled will result in the output gain slidersauto-adjusting apparent output level to match the dry signal level. The output faders will turn blue when theyare auto adjusting level. This is useful to A/B the effect of Ozone processing. Unlike the legacy auto gainbehavior, we recommend turning Gain Match on and off as needed rather than keeping it enabled all the time.This behavior does affect the output of Ozone.
Meter Type
Choose from one of the following options to set the meter type displayed in the I/O meters:
- RMS: RMS (Root Mean Square) is a software-based implementation of an analog-style level meter. Usingdifferent integration times, you can model popular VU or PPM meters. The RMS meter displays the averagelevel calculated over a short window of time. The RMS meter readout will typically be lower than anequivalent PPM meter (Digital/Analog), since it is averaging peaks into the overall loudness.
- PEAK: The Peak meter is a fast meter that measures instantaneous maximum sample value or peak analogwaveform values, depending on the “detect inter-sample peaks” checkbox. If you are tracking the peaks forpossible clipping, the Peak meter is appropriate.
- RMS + PEAK: This is a combined RMS and Peak meter. This meter displays a lower bright bar representingthe average level (RMS) and a higher dimmer bar representing peak level. There is also a moving line abovethe bar representing the most recent peak level or peak hold.
- K-SYSTEM: Ozone 9 supports Bob Katz’s K-System metering with simultaneous peak and RMS displays.
- MOMENTARY: This measurement is a calculation of loudness over the course of 400ms.
- SHORT TERM: This measurement is a calculation of loudness over the course of 3 seconds.
- INTEGRATED: This measurement is a calculation of loudness over the course of an indefinite period oftime.
Meter Scale
Choose from one of the following options to set the range and scale of the I/O Meters:
- dB (Linear): Decibel scale presented linearly from -60 dB to 0.
- dB (Non-linear): Full decibel scale (dBfs) presented non-linearly.
- BS.1771: Loudness scale recommended by the ITU that spans from -45 LUFS to -14.0 LUFS.
- EBU +9: Loudness scale recommended as a default by the EBU that spans from -41.0 LUFS to -14.0 LUFS.
- EBU +18: Loudness scale recommended for material with a wide Loudness Range by the EBU that spans from-59.0 LUFS to -5.0 LUFS.
Meter Source
The following meter source options are available: Stereo and Mid/Side. The I/O meters displayStereo information by default. When the I/O meters are in Mid/Side mode, the meter in the centerrepresents the Mid channel level information and the meters on the left and right represents Side channellevel information.
Gain sliders control Left/Right gain in Mid/Side mode
The input and output gain sliders always control the left and right input/output gain, regardlessof the Meter Source selection.
Peak Hold Time (ms)
Choose from the following options to set how many consecutive samples of audio must exceed 0 dBFS (full scale)before registering as a peak: 5 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, and Infinite.
Integration time (ms)
Choose from the following options to specify the integration time for the RMS calculation: 10 ms, 50 ms, 300ms (VU), 1,475 ms, 2,650 ms, 3,825 ms, and 5,000 ms. In most RMS meters, the integration time is set toaround 300 ms.
Readout
Selects whether the peak hold section of the meters displays the current peak status (current) or insteaddisplays the highest peak that has occurred in the audio file (max peak).
Show Peak Hold
Displays peak hold bars in the I/O meters.
Each purchased copy of Nectar contains a unique serial. After downloading Nectar directly from iZotope or another re-seller the serial number will be e-mailed along with the link to download the product. The serial number should resemble: SN-NECTAR2-XXXX-XXXX-XXXX-XXXX
Launching the Authorization Wizard
The first time you open Nectar 2, the Authorization Wizard will appear. You can choose to either authorize Nectar or use it in Trial mode for evaluation purposes. Please use your supplied Nectar serial number to fully authorize your product.
Trial vs. Demo Mode
For the first 10 days after the first instantiation, Nectar 2 will run in Trial mode, which offers full functionality. After 10 days, Nectar will revert to Demo mode. In Demo mode, Nectar will periodically mute audio output.
Authorizing Your Copy of Nectar Online
After opening Nectar and launching the Authorization Wizard, the following steps will complete the authorization process online:
1. First, click on 'Authorize'.
2. Next, enter the serial number emailed to you. It should look like this:
SN-NECTAR-XXXX-XXXX-XXXX-XXXX
3. You must also enter your name and a valid e-mail address.
Make note of the e-mail address you use to authorize your license. Your license and iZotope account will be linked directly to this e-mail address.
Note: Clicking the 'Advanced' button reveals a set of options that allow you to store your Nectar authorization on a portable hard drive or flash drive. Click here for more information on these options.
4. When you have confirmed that your serial number and e-mail information is accurate, click once more on 'Authorize'.
5. Lastly, click on 'Submit' in order to send your authorization message to the iZotope servers. If the authorization is accepted, click on the 'Finish' button to complete the authorization.
Authorizing Your Copy of Nectar Offline
Some customers choose to keep their audio workstations offline, and a simple offline authorization option has been included. After opening Nectar and launching the Authorization Wizard, the following steps will complete the authorization process offline:
1. When first prompted to authorize Nectar, click on 'Authorize'
2. Next, click on the option for 'Offline Authorization' at the bottom of the authorization window, select 'Authorize with iZotope challenge/response' and click next.
3. You will be given a unique Challenge Code that is specific to your computer only. Write down or make a copy of the exact Challenge Code. It will look like this:
IZ-NECTAR2-XXXXXXXX-XXXX-XXXX
4. Next, using a system with internet access, login to your customer account at the iZotope website: http://www.izotope.com/store/account.asp
5. Click the 'Activate Software with a Serial Number' button, enter your full serial number and click 'Submit'.
6. Select the 'Challenge/Response' option and click on 'Submit'.
7. Read the License Agreement and click 'Agree' if you find it agreeable.
8. Now enter your full Challenge Code copied in step 3.
9. After submitting your Challenge Code, you will receive a unique Response Code. The response code will look like this: IZ-NECTAR2-XXXX-XXXX-XXXX
Write this response code or save a text file with the response code onto a flash drive.
10. Type or paste the Response Code into the text field of Step 3 in the Offline Authorization window.
11. Click ‘Next’ to authorize Nectar .
12. You should now receive a message that your authorization has been successful and may click Finish to begin using Nectar .
iLok Support
Nectar does support iLok. Our plug-ins will be able to detect iLok keys and assets if you already use iLok and PACE software on your system. If you don't already have PACE or iLok, we will not install any PACE or iLok software to your system, and iLok authorizations will be unavailable.
Authorizing Nectar with iLok
1. When first prompted to authorize Nectar 2, click on 'Authorize'
2. Next, enter the serial number emailed to you. It should look like like this:
SN-NECTAR2-XXXX-XXXX-XXXX-XXXX
3. You must also enter your name and a valid e-mail address.
Make note of the e-mail address you use to authorize your license. Your license and iZotope account will be linked directly to this e-mail address.
Where Does Izotope Product Portal Downloads Store Files For Windows 7
4. Select 'Use iLok Authorization' and enter your iLok ID.
5. When you have confirmed that all your information is accurate, click once more on 'Authorize'.
6. Lastly, click on 'Submit' in order to send your authorization message to the iZotope servers
7. You will now be instructed to log in to your iLok account and transfer your Nectar license to your iLok.
8. When you have completed this step and have your iLok connected to the computer on which you want to use Nectar , click 'Next'.
9. You should now receive a message that your authorization has been successful and may click Finish to begin using Nectar .
Where Does Izotope Product Portal Downloads Store Files For Mac
Nectar 2 Vocal Production Suite
If you purchased Nectar 2 Vocal Production Suite, you will also receive the Nectar 2 Pitch Editor and Nectar 2 Breath Control plug-ins. By authorizing your main Nectar 2 plug-in your Pitch Editor and Breath Control plug-ins will also be authorized.
Web Help
Should you encounter any problems during authorization please consult our online portal with additional information:
Where Does Izotope Product Portal Downloads Store Files Online
Contact Support
Should you not be able to resolve your authorization issue please contact the customer at support@izotope.com.
Where Does Izotope Product Portal Downloads Store Files Free
iZotope's highly trained support team is committed to responding to all requests within one (1) business day and frequently respond faster. Please try to explain your problem with as much detail and clarity as possible.